| Polakker | Nominell strøm | Kontrollspenning (V AC) (50 Hz) | Strømforbruk | Maksimal effekt | ||
| AC-7a | AC-7b | Hold ut | Trekk inn | |||
| 1P | 16A | 6A | 230–240 | 2,7VA | 9,2VA | 1,2 W |
| 20A | 7A | 230–240 | 2,7VA | 9,2VA | 1,2 W | |
| 25A | 9A | 230–240 | 2,7VA | 9,2VA | 1,2 W | |
| 2P | 16A | 6A | 230–240 | 2,7VA | 9,2VA | 1,2 W |
| 20A | 7A | 230–240 | 2,7VA | 9,2VA | 1,2 W | |
| 25A | 9A | 24 | 3,8VA | 15VA | 1,3 W | |
| 230–240 | 2,7VA | 9,2VA | 1,2 W | |||
| 32A | 12A | 230–240 | 4,6VA | 34VA | 1,6 W | |
| 40A | 18A | 230–240 | 4,6VA | 34VA | 1,6 W | |
| 63A | 25A | 230–240 | 4,6VA | 34VA | 1,6 W | |
| 100A | - | 230–240 | 6,5VA | 53VA | 2,1 W | |
| 3P | 16A | 6A | 230–240 | 4,6VA | 34VA | 1,6 W |
| 20A | 7A | 230–240 | 4,6VA | 34VA | 1,6 W | |
| 25A | 9A | 230–240 | 4,6VA | 34VA | 1,6 W | |
| 32A | 12A | 230–240 | 6,5VA | 53VA | 2,1 W | |
| 40A | 18A | 230–240 | 6,5VA | 53VA | 2,1 W | |
| 63A | 25A | 230–240 | 6,5VA | 53VA | 2,1 W | |
| 4P | 16A | 6A | 230–240 | 4,6VA | 34VA | 1,6 W |
| 20A | 7A | 230–240 | 4,6VA | 34VA | 1,6 W | |
| 25A | 9A | 24 | 4,6VA | 34VA | 1,6 W | |
| 230–240 | 4,6VA | 34VA | 1,6 W | |||
| 32A | 12A | 230–240 | 6,5VA | 53VA | 2,1 W | |
| 40A | 18A | 230–240 | 6,5VA | 53VA | 2,1 W | |
| 63A | 25A | 230–240 | 6,5VA | 53VA | 2,1 W | |
| 100A | - | 230–240 | 13VA | 106VA | 4,2 W | |
| Polakker | Nominell strøm (A) | ESKE ANTALL | KARTONG ANTALL | Automatisk kontaktor | Manuell kontaktor | KARTONGSSTØRRELSE (mm) | ||
| GW (kg) | NV (kg) | GW (kg) | NV (kg) | |||||
| AC 1P | 16 | 12 | 120 | 15.4 | 13,8 | 15.4 | 13,8 | 500x260x190 |
| 20 | 12 | 120 | 15,52 | 13,92 | 15,52 | 13,92 | 500x260x190 | |
| 25 | 12 | 120 | 15,52 | 13,92 | 15,52 | 13,92 | 500x260x190 | |
| AC 2P | 16 | 12 | 120 | 15.4 | 13,8 | 15.4 | 13,8 | 500x260x190 |
| 20 | 12 | 120 | 15,52 | 13,92 | 15,52 | 13,92 | 500x260x190 | |
| 25 | 12 | 120 | 15,52 | 13,92 | 15,52 | 13,92 | 500x260x190 | |
| 32 | 6 | 60 | 15.04 | 13.44 | 15.04 | 13.44 | 500x260x190 | |
| 40 | 6 | 60 | 15.04 | 13.44 | 15.04 | 13.44 | 500x260x190 | |
| 63 | 6 | 60 | 15.1 | 13,5 | 15.1 | 13,5 | 500x260x190 | |
| 100 | 4 | 40 | 14.08 | 12.48 | - | - | 500x260x190 | |
| AC 3P | 16 | 6 | 60 | 13,9 | 12.3 | 13,9 | 12.3 | 500x260x190 |
| 20 | 6 | 60 | 13,9 | 12.3 | 13,9 | 12.3 | 500x260x190 | |
| 25 | 6 | 60 | 13,9 | 12.3 | 13,9 | 12.3 | 500x260x190 | |
| 32 | 4 | 40 | 14,76 | 13.16 | 14,76 | 13.16 | 500x260x190 | |
| 40 | 4 | 40 | 14,76 | 13.16 | 14,76 | 13.16 | 500x260x190 | |
| 63 | 4 | 40 | 14,76 | 13.16 | 14,76 | 13.16 | 500x260x190 | |
| AC 4P | 16 | 6 | 60 | 13,9 | 12.3 | 13,9 | 12.3 | 500x260x190 |
| 20 | 6 | 60 | 13,9 | 12.3 | 13,9 | 12.3 | 500x260x190 | |
| 25 | 6 | 60 | 13,9 | 12.3 | 13,9 | 12.3 | 500x260x190 | |
| 32 | 4 | 40 | 14,76 | 13.16 | 14,76 | 13.16 | 500x260x190 | |
| 40 | 4 | 40 | 14,76 | 13.16 | 14,76 | 13.16 | 500x260x190 | |
| 63 | 4 | 40 | 14,76 | 13.16 | 14,76 | 13.16 | 500x260x190 | |
| 100 | 2 | 30 | 20.2 | 18.6 | - | - | 500x260x190 | |
| DC 2P | 16 | 12 | 120 | 15,52 | 13,92 | 15,52 | 13,92 | 500x260x190 |
| 20 | 12 | 120 | 15,52 | 13,92 | 15,52 | 13,92 | 500x260x190 | |
| 25 | 12 | 120 | 15,52 | 13,92 | 15,52 | 13,92 | 500x260x190 | |
| AC/DC 2P | 32 | 6 | 60 | 15.19 | 13,59 | 15.19 | 13,59 | 500x260x190 |
| 40 | 6 | 60 | 15.19 | 13,59 | 15.19 | 13,59 | 500x260x190 | |
| 63 | 6 | 60 | 15.19 | 13,59 | 15.19 | 13,59 | 500x260x190 | |
| AC/DC 4P | 16 | 6 | 60 | 14.05 | 12.45 | 14.05 | 12,45 | 500x260x190 |
| 20 | 6 | 60 | 14.05 | 12.45 | 14.05 | 12.45 | 500x260x190 | |
| 25 | 6 | 60 | 14.05 | 12.45 | 14.05 | 12.45 | 500x260x190 | |
| 32 | 4 | 40 | 14,86 | 13.26 | 14,86 | 13.26 | 500x260x190 | |
| 40 | 4 | 40 | 14,86 | 13.26 | 14,86 | 13.26 | 500x260x190 | |
| 63 | 4 | 40 | 14,86 | 13.26 | 14,86 | 13.26 | 500x260x190 | |
| AC/DC 4P (dupleksvikling) | 32 | 4 | 40 | 15.2 | 13.6 | 15.2 | 13.6 | 500x260x190 |
| 40 | 4 | 40 | 15.2 | 13.6 | 15.2 | 13.6 | 500x260x190 | |
| 63 | 4 | 40 | 15.2 | 13.6 | 15.2 | 13.6 | 500x260x190 | |