MODELL | HDR-100-12 | HDR-100-15 | HDR-100-24 | HDR-100-48 |
DC spenning | 12v | 15V | 24v | 48v |
Merkestrøm | 7,5A | 6,5A | 4.2A | 2.1A |
Gjeldende rekkevidde | 0~7,5A | 0~6,5A | 0~4,2A | 0~2,1A |
Nominell effekt | 90w | 97,5w | 100,8w | 100,8W |
Rippel og støy (maks.) | 120mVp-p | 120mVp-p | 150mVp-p | 240mVp-p |
Spenning ADJ.område | 12~13,8V | 13,5~18V | 21,6~29V | 43,2~55,2V |
Spenningstoleranse | ±2,0 % | ±1,0 % | ±1,0 % | ±1,0 % |
Linjeregulering | ±1,0 % | ±1,0 % | ±1,0 % | ±1,0 % |
Lastregulering | ±1,0 % | ±1,0 % | ±1,0 % | ±1,0 % |
Oppsett, Rise, Time | 500ms, 60ms/230VAC 500ms, 60ms/115VAC (full belastning) | |||
Hold opp tid | 30ms/230VAC 12ms/115VAC (full belastning) | |||
Spenningsområde | 85~264VAC (277VACusable) 120~370VDC(390VDCusable) | |||
Spenningsområde | 50~60Hz | |||
Effektivitet | 88 % | 89 % | 90 % | 90 % |
AC strøm | 3A/115VAC 1,6A/230VAC | |||
Startstrøm | Kaldstart: 35A/115VAC 70A/230VAC | |||
Overbelastning | 105~150% nominell utgangseffekt | |||
Beskyttet modus: konstant strømmodus, kan automatisk gjenopprettes etter at den unormale belastningen er fjernet | ||||
Overspenning | 14,2~16,2V | 18,8~22,5V | 30~36V | 56,5~64,8V |
Beskyttende modus;Lukk utgangen og start på nytt for å gjenopprette | ||||
Arbeid TEMP | -30~+70ºC | |||
Arbeidsfuktighet | 20~90% RF, ikke-kondenserende | |||
Lagring TEMP fuktighet | -40~+85ºC,10-95%RH,ikke-kondenserende | |||
TEMP.koeffisient | ±0,03 %ºC(0~50ºC) | |||
Vibrasjon | 10~500Hz,2G 10min./1syklus,60min.hver langs X,Y,Z-aksene Installer i samsvar med IEC60068-2-6 | |||
Driftshøyde | 2000m | |||
Overspenningsklasse | I henhold til EN61558 EN50178 EN60664-1, EN62477-1; Høyden kan være så høy som 2000 meter | |||
Tåler spenning | I/PO/P4KVAC | |||
Insolasjonsmotstand | I/PO/P:100M ohm 500VDc / 25ºC/70 % RF | |||
MTBF | ≥856,5K timer.MIL-HDBK-217F(25ºC) | |||
Dimensjon | 70*90*54,5 mm (B*H*D) | |||
Pakking | 0,27 kg; 48 stk/14 kg/0,6 CUFT |